A longitudinal validation of the EQ-5D-5L and EQ-VAS stand-alone component utilising the Oxford Hip Score in the Australian hip arthroplasty population.

Author(s)
Lin, D-Yin
Cheok, Tim Soon
Samson, Anthony J
Kaambwa, Billingsley
Brown, Brigid
Wilson, Christopher
Kroon, Hidde M
Jaarsma, Ruurd
Publication Date
2022-06-20
Abstract
PURPOSE: To evaluate the measurement properties of the Oxford Hip Score (OHS), EQ-5D-5L utility index and EQ-5D-5L visual analogue scale (EQ-VAS) in patients undergoing elective total hip arthroplasty in Australia. METHODS: In this prospective multi-centre study, the OHS and EQ-5D-5L were collected preoperatively, six weeks (6w) and six months (6m) postoperatively. The OHS, EQ-VAS and EQ-5D-5L index were evaluated for concurrent validity, predictive validity (Spearman's Rho of predicted and observed values from a generalised linear regression model (GLM)), and responsiveness (effect size (ES) and standard response mean (SRM)). RESULTS: 362 patients were included in this analysis for 6w and 269 for 6m. The EQ-5D-5L index showed good concurrent validity with the OHS (r = 0.71 preoperatively, 0.61 at 6w and 0.59 at 6m). Predictive validity for EQ-5D-5L index was similar to OHS when regressed (GLM). Responsiveness was good at 6w (EQ-5D-5L index ES 1.53, SRM 1.40; OHS ES 2.16, SRM 1.51) and 6m (EQ-5D-5L index ES 1.88, SRM 1.70; OHS ES 3.12, SRM 2.24). The EQ-VAS returned poorer results, at 6w an ES of 0.75 (moderate) and SRM 0.8. At 6m the EQ-VAS had an ES of 0.92 and SRM of 1.00. It, however, had greater predictive validity. CONCLUSIONS: The EQ-5D-5L index and the OHS demonstrate strong concurrent validity. The EQ-5D-5L index demonstrated similar predictive validity at 6w and 6m, and both PROMs had adequate responsiveness. The EQ-VAS should be used routinely together with the EQ-5D-5L index. The EQ-5D-5L is suitable to quantify health-related quality of life in Australian hip arthroplasty patients.
Affiliation
c/o Department of Anesthesiology, Flinders Medical Centre, Flinders Drive, Bedford Park 5042, Adelaide, SA, Australia. d-yin.lin@sa.gov.au.
College of Medicine and Public Health, Flinders University, Adelaide, SA, Australia. d-yin.lin@sa.gov.au.
Department of Orthopaedic and Trauma Surgery, Alice Springs Hospital, Alice Springs, NT, Australia.
College of Medicine and Public Health, Flinders University, Adelaide, SA, Australia.
c/o Department of Anesthesiology, Flinders Medical Centre, Flinders Drive, Bedford Park 5042, Adelaide, SA, Australia.
Department of Surgery, Royal Adelaide Hospital, Adelaide, SA, Australia.
Faculty of Health and Medical Sciences, Adelaide Medical School, University of Adelaide, Adelaide, SA, Australia.
Citation
J Patient Rep Outcomes. 2022 Jun 20;6(1):71. doi: 10.1186/s41687-022-00482-7.
OrcId
0000-0002-0813-3161
Pubmed ID
https://pubmed.ncbi.nlm.nih.gov/35723750/?otool=iaurydwlib
Link
Volume
6
Title
A longitudinal validation of the EQ-5D-5L and EQ-VAS stand-alone component utilising the Oxford Hip Score in the Australian hip arthroplasty population.
Type of document
Journal Article
Entity Type
Publication

Files:

NameSizeformatDescriptionLink
https://digitallibrary.health.nt.gov.au/nthealthserver/api/core/items/ff00ae3f-b275-4607-b968-04ffaf3f4f91