    4. Accuracy of Tympanic Temperature Measurement in Firefighters Completing a Simulated Structural Firefighting Task.
    Details
    Title

    Accuracy of Tympanic Temperature Measurement in Firefighters Completing a Simulated Structural Firefighting Task.

    Link to article in PubMed
    https://pubmed.ncbi.nlm.nih.gov/26451779/?otool=iaurydwlib
    Author(s)
    Keene, Toby
    Brearley, Matt
    Bowen, Beth
    Walker, Anthony
    Abstract
    INTRODUCTION: In the course of their duties, firefighters risk heat stroke and other medical conditions due to exertion in high-temperature environments. Infrared tympanic temperature measurement (TTym) is often used by Emergency Medical Services (EMS) to assess the core body temperature of firefighters. The accuracy of TTym in this setting has been called into question. Hypothesis/Problem This study aimed to examine the accuracy of TTym for core body temperature assessment at emergency firefighting events compared with gastrointestinal temperature measurement (TGI) as measured by ingestible thermometers.
    METHODS: Forty-five (42 male, three female) professional urban firefighters from an Australian fire service completed two 20-minute work periods in a 100°C (± 5°C) heat chamber while wearing personal protective clothing (PPC) and breathing apparatus (weighing approximately 22 kg). Measurements were taken immediately before entering, and on exiting, the heat chamber. Tympanic temperature was assessed by an infrared tympanic thermometer and TGI was measured by ingestible sensor and radio receiver.
    RESULTS: Complete data were available for 37 participants. Participant temperatures were higher on exiting the heat chamber than at baseline (TTym: 35.9°C (SD=0.7) vs 37.5°C (SD=0.8); TGI: 37.2°C (SD=0.4) vs 38.6°C (SD=0.5)). Tympanic temperature underestimated TGI on average by 1.3°C (SD=0.5) before entering the chamber and by 1.0°C (SD=0.8) following the exercise. Using pooled data, the average underestimation was 1.2°C (SD=0.7).
    CONCLUSION: Tympanic thermometers cause an unreliable measure of core body temperature for firefighters engaged in fire suppression activities. Accurate and practical measures of core body temperature are required urgently.
    Publication information
    Prehosp Disaster Med . 2015 Oct;30(5):461-5. doi: 10.1017/S1049023X15005038.
    Date Issued
    2015-10-01
    Type
    Journal Article
    Subjects
    EMS Emergency Medical Services
    Emergency Medical Services
    PPC personal protective clothing
    SCBA self-contained breathing apparatus
    TGI gastrointestinal temperature measurement
    TTym tympanic membrane temperaturemeasurement
    body temperature
    firefighters
    thermometers
    MESH Subject
    Adult
    Australia
    Body Temperature
    Ear, Middle
    Emergency Medical Services
    Female
    Firefighters
    Humans
    Infrared Rays
    Male
    Middle Aged
    Protective Clothing
    Simulation Training
    Thermometers
    Tympanic Membrane
    Journal Title
    Prehospital and disaster medicine
    DOI
    10.1017/S1049023X15005038
    Permanent link to this record
    https://hdl.handle.net/10137/15368
    ISSN
    1945-1938
    Owning collection
    Research and Conference Publications

    NT Health Library Services acknowledges the Traditional Custodians of Country throughout the Northern Territory and recognises their continuing cultural and spiritual connections to the lands, waters, and communities. We pay our respects to elders past, present and emerging, and extend that respect to all Aboriginal and Torres Strait Islander people across the Northern Territory and beyond, many of whom are represented in our collections.