Relative radio-opacity of commonly consumed fish species in South East Queensland on lateral neck x-ray: an ovine model.
Link to article in PubMed
Author(s)
Davies, William
Bate, Patricia
Abstract
To determine the relative radio-opacity on plain x-ray of bones of fish species commonly consumed in South East Queensland. A cadaveric sheep model was used to mimic the soft tissues of a human neck. Bones of 10 fish species were placed in the paratracheal tissues and adjacent to the larynx. X-rays were taken and the images (including four control images with no bones) were incorporated into a Microsoft PowerPoint presentation to be interpreted by emergency specialists and registrars. Observers were blinded to which specimens contained fishbones and which did not. Sensitivity and specificity of plain x-rays for detecting impacted fishbones. Significant interobserver variability was identified. Despite this, the overall specificity of plain x-rays was 90%. The sensitivity of the technique was 79% overall, but varied significantly between fish species. Lateral soft tissue neck x-ray is an appropriate screening tool in cases of a suspected impacted fishbone. If a fishbone is identified on x-ray, the patient should be referred for endoscopy without further imaging. X-ray may be of limited value in cases of Dory or Spanish mackerel bone ingestion. In such cases, a computed tomography scan should be the first-line investigation.
Publication information
Med J Aust . 2009 Dec;191(11-12):677-80. doi: 10.5694/j.1326-5377.2009.tb03378.x.
Date Issued
2009-12-01
Type
Journal Article
Journal Title
The Medical journal of Australia