Repository logo

  • Help
  • Log In(current)
    1. Home
    2. NT Health Research
    3. Research and Conference Publications
    4. Assessment of ablation catheter contact on valve annulus: Implications on accessory pathway ablation.
    Details
    Title

    Assessment of ablation catheter contact on valve annulus: Implications on accessory pathway ablation.

    Link to article in PubMed
    https://pubmed.ncbi.nlm.nih.gov/30914382/?otool=iaurydwlib
    Author(s)
    Choo, Wai Kah
    Raju, Hariharan
    Lipton, Jonathan
    Bates, Matthew
    Kistler, Peter
    Sparks, Paul
    Morton, Joseph
    Kalman, Jonathan
    Abstract
    BACKGROUND: Catheter-tissue contact force is an important factor influencing lesion size and efficacy and thereby potential for arrhythmia recurrence following accessory pathway (AP) radiofrequency ablation. We aim to evaluate adequacy and perception of catheter contact on the tricuspid and mitral annuli.
    METHODS: Data were collected from 42 patients undergoing catheter ablation. Operators were blinded to contact force information and reported perceived contact (poor, moderate, or good) while positioning the catheter at four tricuspid annular sites (12, 9, 6 and 4 o'clock positions; abbreviated as TA12, TA9, TA6 and TA4) and three mitral annular sites (3, 5 and 7 o'clock positions; abbreviated as MA3, MA5 and MA7) through long vascular sheaths.
    RESULTS: The highest and lowest mean contact forces were obtained at MA7 (13.3 ± 1.7 g) and TA12 (3.6 g ± 1.3 g) respectively. Mean contact force on tricuspid annulus (6.1 g ± 0.9 g) was lower than mitral annulus (9.8 ± 0.9 g) locations (p = 0.0036), with greater proportion of sites with <10 g contact force (81.7% vs 60.4%; p = 0.0075). Perceived contact had no impact on measured mean contact force for both mitral and tricuspid annular positions (p = 0.959 and 0.671 respectively). There was correlation of both impedance and atrial electrogram amplitude with contact force, though insufficient to be clinically applicable.
    CONCLUSION: A high proportion of annular catheter applications have low contact force despite being performed with long vascular sheaths in the hands of experienced operators. In addition, there was no impact of operator perceived contact force on actual measured contact force. This may carry implications for success of AP ablation.
    Publication information
    Indian Pacing Electrophysiol J . 2019 May-Jun;19(3):84-89. doi: 10.1016/j.ipej.2019.03.007. Epub 2019 Mar 23.
    File(s)
    Loading...
    Thumbnail Image
    Download
    Name

    Assessment of ablation catheter contact on valve annulus.pdf

    Description
    Re-used under a Creative Commons Attribution License: https://creativecommons.org/licenses/by-nc-nd/4.0/
    Size

    588.82 KB

    Format

    Adobe PDF

    Checksum

    (MD5):af4223afdffdca2cbbd6d9221d93b9c7

    Date Issued
    2019-05-01
    Type
    Journal Article
    Subjects
    Ablation
    Accessory pathway
    Contact force
    Mitral annulus
    Tricuspid annulus
    Journal Title
    Indian pacing and electrophysiology journal
    DOI
    10.1016/j.ipej.2019.03.007
    Permanent link to this record
    https://hdl.handle.net/10137/15114
    ISSN
    0972-6292
    Owning collection
    Research and Conference Publications

    NT Health Library Services acknowledges the Traditional Custodians of Country throughout the Northern Territory and recognises their continuing cultural and spiritual connections to the lands, waters, and communities. We pay our respects to elders past, present and emerging, and extend that respect to all Aboriginal and Torres Strait Islander people across the Northern Territory and beyond, many of whom are represented in our collections.

    © 2025 Northern Territory Government of Australia